Home · Open Lab · Lot RGX-26-RGNX-750
RGX-26-RGNX-750Superseded
Semax · 10 MG · Cognitive Research · COA NS-2026-05175

Release test results

99.553%HPLC purity · meets ≥ 99.5% spec
Mass-spec identityConfirmed · 10.03 mg
Related impurities (total)0.447%
Endotoxin<1.0 EU/mg
HPLC retention time6.56 min
MethodHPLC + LC-MS
ResultPass · meets spec

Lot record

CompoundSemax
Presentation10 MG
Lot numberRGX-26-RGNX-750
COA numberNS-2026-05175
Test date30 Mar 2026
Release date02 Apr 2026
Independent labNordicstar Labs
StatusSuperseded

Semax — lot history

LotPresentationTestedHPLC purityStatus
RGX-26-RGNX-10495 MGJul 14, 202699.599%Current
RGX-26-RGNX-105010 MGJul 14, 202699.561%Current
RGX-26-RGNX-750 this lot10 MGMar 30, 202699.553%Superseded
RGX-26-RGNX-7515 MGMar 28, 202699.629%Superseded
RGX-26-RGNX-65010 MGJan 2, 202699.660%Superseded
RGX-25-RGNX-6515 MGDec 31, 202599.736%Superseded
!
Research use only

This lot record documents a research compound sold for laboratory use only — not for human or animal consumption. Results are as tested by Nordicstar Labs; retained samples are archived for five years. Research Use Agreement →