Release test results
99.760%HPLC purity · meets ≥ 99.5% spec
Mass-spec identityConfirmed · 5.01 mg
Related impurities (total)0.240%
Endotoxin< 0.05 EU/mg
HPLC retention time6.68 min
MethodHPLC + LC-MS
ResultPass · meets spec
Lot record
Compound5-Amino-1MQ
Presentation5 MG
Lot numberRGX-26-5-770
COA numberNS-2026-05135
Test date17 Apr 2026
Release date20 Apr 2026
Independent labNordicstar Labs
StatusSuperseded
5-Amino-1MQ — lot history
| Lot | Presentation | Tested | HPLC purity | Status |
|---|---|---|---|---|
| RGX-26-5-1030 | 5 MG | Jul 24, 2026 | 99.586% | Current |
| RGX-26-5-1031 | 50 MG | Jul 23, 2026 | 99.769% | Current |
| RGX-26-5-769 | 50 MG | Apr 18, 2026 | 99.684% | Superseded |
| RGX-26-5-770 this lot | 5 MG | Apr 17, 2026 | 99.760% | Superseded |
| RGX-26-5-670 | 5 MG | Jan 20, 2026 | 99.646% | Superseded |
| RGX-26-5-669 | 50 MG | Jan 9, 2026 | 99.708% | Superseded |
!
Research use only
This lot record documents a research compound sold for laboratory use only — not for human or animal consumption. Results are as tested by Nordicstar Labs; retained samples are archived for five years. Research Use Agreement →